Revamp

Project Description

Adjusting the piping to the exhaust air volume of the new melt tank, optimizing flow behavior and filter discharge

Implementation

  • Redesign of the exhaust air duct with a primary focus on preventing dust deposition
  • Adjustment of the feed points for hydrated lime and urea
  • Use of slide valves instead of dampers
  • New raw gas and fresh air dampers, including electric actuators
  • Conversion of the filter discharge system to a significantly larger, specially designed rotary valve
  • Retrofitting of a dust measurement system for filter rupture detection
  • Mechanical modifications, including insulation, performed by a specialized contractor; electrical modifications
  • Commissioning, PLC control program, HMI interface